FM200 Fire Extinguishing System Without Residue For Data Center

1 세트
MOQ
협상 가능
가격
FM200 Fire Extinguishing System Without Residue For Data Center
풍모 갤러리 제품 설명 따옴표를 요구하십시오
풍모
제품 사양
저장 압력: 4.2MPA
분사 시간: ≤10s
충진 밀도: ≤950kg/m3
공칭 압력: 5.3MPa
테스트 압력: 8.4MPa
작업력: DC 24V 1.6A
작업 온도: 0C~50C
보호 영역은 이릅니다: 적당한 비율로 조절하세요 : ≤800m2 ; 크기 : ≤3600m3
시작 모드: 자동, 전기적 설명서, 기계적 설명서
실린더 볼륨: 40L、70L、100L、120L、150L、180L
기본 정보
원래 장소: 중국
브랜드 이름: Air Giant
인증: CAL,CMA,CNAS,ILAC-MRA,CCC
모델 번호: QMP40/4.2, QMP70/4.2, QMP100/4.2, QMP120/4.2, QMP150/4.2, QMP180/4.2
결제 및 배송 조건
포장 세부 사항: 버블 백이나 종이가있는 합판 외부 상자
배달 시간: 10-15 근무일
지불 조건: L/C, D/P, T/T, Western Union, PayPal, 신용 카드
공급 능력: 1주일에 28000개 세트
제품 설명

FM200 Fire Extinguishing System Without Residue For Data Center



Description


The fire extinguishing effect of FM200 is less affected by environmental factors, mainly due to its fast response time and efficient fire extinguishing ability. However, it is important to note that FM200 has a high global warming potential (GWP), so although it is not harmful to the ozone layer, its environmental impact is of concern. To reduce the environmental impact, steps are being taken to promote the responsible use of FM200 and to explore alternative fire extinguishing agents with lower GWP.


Components


1. Mechanical parts: cylinder with container valve, frame for cylinder group, driving cylinder, frame for driving device, high pressure hose etc. It is mainly used for storing fm200 agent

2. Electrical parts: smoke detector, heat detector, bell etc.

3. Pipe fittings: conduit, connector, elbow, flange etc.

FM200 Fire Extinguishing System Without Residue For Data Center 0


Working  principle: 


The FM200 Fire Suppression System is also highly effective at extinguishing fires. It works by interrupting the chemical chain reaction that occurs during a fire, preventing the fire from spreading and extinguishing it quickly. The system can extinguish fires within 10 seconds, providing a rapid response that can help to minimize damage and downtime.

 

Here is the illustration of working principle to whole system

FM200 Fire Extinguishing System Without Residue For Data Center 1


Application: 


•   Computer room, communication room, power distribution room, library, archives,

    Museum, etc.

 

•   Be used for electrical fire, liquid fire, solid fire, gas fire which can be cut off the gas

source before extinguishing occur, etc.


FM200 Fire Extinguishing System Without Residue For Data Center 2



Advantages


The FM200 Fire Suppression System is one of the most advanced fire suppression systems available today. It is designed to provide a fast and effective response to fire emergencies while minimizing damage to critical assets and preserving the safety of people and the environment.

 

One of the key advantages of the FM200 Fire Suppression System is its chemical and physical properties. The chemical agent, HFC-227ea, is a colorless, odorless, and electrically non-conductive gas that is safe for use in occupied spaces. It is also non-corrosive, non-toxic, and does not leave any residue or oily deposits after use. This makes it an ideal choice for use in sensitive areas such as data centers and museums.


Packages


We always pack it with polyfoam firstly and then put it into a wooden case. Sometimes, in order to meet with customers or the safety requirement, we will make a pallet for the goods.


FM200 Fire Extinguishing System Without Residue For Data Center 3


추천된 제품
우리와 연락하기
담당자 : Mr. Missaya Lu
전화 번호 : +86 188 1945 1181
남은 문자(20/3000)